Ingenieria Grupo Empresarial Actual S.A. De C.V.


Go to content

Main menu:


Specialty - Nuclear 1

Equipos De Bombeo > Specialty Pumps > Specialty - Nuclear

DFSS and DVSS Nuclear
Radially Split,
Single Stage


CAM Nuclear
Between Bearings,
Radially Split, Multistage


WDF Nuclear
Vertical Single Stage



Standards
ASME Section III, Class 1 Nuclear
Operating Parameters
• Flows to 24 500 m3/h (108 000 gpm)
• Heads to 250 m (815 ft)
• Pressures to 170 bar (2500 psi)
• Temperatures to 300°C (580°F)
• Speeds to 1800 rpm
• Power rating to 9400 kW (12 600 hp)
Services
• Primary coolant
• Reactor coolant
• Primary heat transport
Features
• Fourth generation design
• One-piece cast pump casing
• Double volute design case for BWR
and PHWR
• Diffuser with torus-type design
casing for PWR
• Upgraded rotating element
– One-piece welded shaft-impellerjournal
assembly
– Fully machined and balanced
as single rotating unit
• Hydrostatic-pressurized radial bearing
– Operates submerged in radioactive
system water at loop temperature
of approximately 300°C (580°F)
See Bulletin FPD-2

Standards
• ASME Section III, Class 2 Nuclear
Operating Parameters
• Flows to 45 m3/h (200 gpm)
• Heads to 1920 m (6300 ft)
• Pressures to 200 bar (3000 psi)
• Temperatures to 120°C (250°F)
Services
• CVCS charge
• Safety injection
• Control rod drive
Features
• Multistage, double casing design
• Unique, compact design patented
modular impellers
– Low-flow stability and reliability
over a wide range of flows
– No surging or pulsations
• Ball-ball construction
• Dry disk spacer coupling
• Flanged axial thrust-balancing device
• Modularized assembly and
disassembly may be conducted
without the use of a torch
• Forged barrel with no
attachment welds
• Cartridge mechanical seals with
no attachment welds
See Bulletin FPD-2

Standards
• ASME Section III, Class 2 and 3
Nuclear
Operating Parameters
• Flows to 900 m3/h (4000 gpm)
• Heads to 245 m (800 ft)
Services
• Containment spray
• Low pressure safety injection
• Residual heat removal
• Pressurized and boiling water reactors
for N-stamp safety applications
Features
• Vertical, single stage design
• Bottom suction, horizontal discharge
• Forged diffuser casing design
• Optimized hydraulic performance
• Unique spacer coupling design
• Mechanical seal replacement without
motor or casing cover removal
• Upgraded rotor design
– Radial bearing located between
coupling and seal
– Reduced shaft deflection
– Improved pump and mechanical
seal life and reliability
• Cartridge mechanical seal
• Reduced assembly time
See Bulletin FPD-2